AVERTISSEMENT : RISQUE DE
BASCULEMENT. NE REGROUPEZ JAMAIS
LES TROIS BRAS D’INSTRUMENTS
ENSEMBLE SUR UN CÔTÉ DU SUPPORT.
DISTRIBUEZ LE POIDS DES INSTRUMENTS
AUSSI ÉGALEMENT QUE POSSIBLE. ÉVITEZ
UN MOUVEMENT RAPIDE OU VIOLENT DES
BRAS D’INSTRUMENTS.
2.2. Instrument Console/Base Cap
CAUTION- The power supply cord should
not be connected to the power supply during
the installation process.
PRÉCAUTION : Le cordon d’alimentation
ne devrait pas être connecté au bloc
d’alimentation durant le processus
d’installation.
2. INSTALLATION
2.1. Unpacking
2.1.1. Base Unit
2.1.1.1 Remove all external shipping tapes and wrappings.
Remove the Base Unit from the skid and set it in the desired,
nal location.
2.1.1.2 Loosen the two screws that hold the Back Cover
(Figure 1) in place, located in the bottom of the Cover.
Remove the screw located in the top of the Back Panel.
Panels lift off the Base Unit.
2.1.1.3. Squeeze the Slit Lamp Arm
Lock Release Lever
(Figure 1) and at the same time push down on Slit Lamp
Arm. Arm should move approximately 1/4 inch. Release the
Lock Release Lever
to set the Slit Lamp Arm lock.
2.1.1.4. At the rear of the Base Unit, remove the wood
brace beneath the counter balance weights and the cords
which hold incremental weights to the large weight. While
pushing rmly down (50 pounds force) on the Slit Lamp
Arm, again squeeze the
Lock Release Lever
. Allow the Slit
Lamp Arm to rise to its full height and again release the
Lock Release Lever
.
WARNING- TO AVOID PERSONAL INJURY
OR DAMAGE TO THE INSTRUMENT STAND
CAUSED BY THE STAND TIPPING OVER, DO
NOT OVERLOAD THE REFRACTOR ARM,
THIRD ARM, OR SLIT LAMP ARM.
AVERTISSEMENT : POUR ÉVITER UNE
BLESSURE OU UN DOMMAGE AU SUPPORT À
INSTRUMENT CAUSÉ PAR UN RENVERSEMENT
DU SUPPORT, NE SURCHARGEZ PAS LE BRAS
RÉFRACTEUR, LE TROISIÈME BRAS OU LE
BRAS DE LA LAMPE À FENTE.
WARNING: WITH WEIGHT BRACE REMOVED,
THE SLIT LAMP ARM ASSEMBLY WILL
RISE ABRUPTLY IF RELEASE LEVER IS
DEPRESSED.
AVERTISSEMENT : LE SUPPORT LESTÉ ÉTANT
RETIRÉ, L’ASSEMBLAGE DU BRAS DE LA
LAMPE À FENTE SE LÈVERA ABRUPTEMENT
SI LE LEVIER DE DÉGAGEMENT EST PRESSÉ.
WARNING – TIP-OVER HAZARD: NEVER
GROUP THREE INSTRUMENT ARMS
TOGETHER ON ONE SIDE OF THE STAND.
DISTRIBUTE INSTRUMENT WEIGHT AS
EQUALLY AS PRACTICAL. AVOID FAST OR
FORCEFUL MOVEMENT OF INSTRUMENT
ARMS.
IN-7900
7
FIGURE 1
Instrument
Console or
Base Cap
Support
Column
Release Lever
Handle
Slit Lamp Arm
Handle
Back
Cover
Base
Unit
Wood Brace
(Inside)
Third Arm
Refractor
Arm
Overhead
Lamp
Monitor
Arm
24”
(609.6 mm)
16”
(406.4 mm)
1/2”