37: Forward jog
38: Reverse jog
39: Counter input
40: Counter reset
41: PID deactivation
46: User parameter set selection
48: Motor overheating error N.O. contact input
49: Motor overheating error N.C. contact input
50: Motor overheating warning N.O. contact input
51: Motor overheating warning N.C. contact input
Setting range of H8.06:
0: Polarity inactive
1: Polarity active without direction control
2: Polarity active with direction control
Setting range of H8.20, H8.21, H8.22:
0: Converter ready
1: Converter running
2: Converter DC-braking
3: Converter running at zero speed
4: Speed arrival
5: Frequency level detection signal (FDT1)
6: Frequency level detection signal (FDT2)
7: Simple PLC stage complete
8: Simple PLC cycle complete
10: Converter undervoltage
11: Converter overload pre-warning
12: Motor overload pre-warning
13: Converter stop by external error
14: Converter error
15: Converter OK
16: Counter target value arrival
17: Counter middle value arrival
18: PID reference engineering value arrival
20: Torque control mode
21: Parameter setting from communication
25: Converter error or warning
Bosch Rexroth AG
Start-up
EFC 3610 / EFC 5610
74/87
DOK-RCON03-EFC-X610***-QU11-EN-P

Table of Contents

Other manuals for REXROTH EFC 3610 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH EFC 3610 Series and is the answer not in the manual?

REXROTH EFC 3610 Series Specifications

General IconGeneral
BrandREXROTH
ModelEFC 3610 Series
CategoryDC Drives
LanguageEnglish

Related product manuals