Code Name Setting range Default Min. Attri.
H8.39 EAO curve minimum -100.0 %...[H8.41] 0.0 0.1 Run
H8.40 EAO curve minimum value -100.0…100.0 % 0.00 0.01 Run
H8.41 EAO curve maximum [H8.39]...100.0 % 100.0 0.1 Run
H8.42 EAO curve maximum value -100.0…100.0 % 100.0 0.1 Run
H8.87 I/O card output channel diagnosis
0: Inactive
1: EAO diagnosis
2: EDO diagnosis
3: ERO diagnosis/EDO2 diag-
nosis
4: All output diagnosis
1 Stop
Setting range of H8.00...H8.04:
0: No function assigned
1: Multi-speed control input 1
2: Multi-speed control input 2
3: Multi-speed control input 3
4: Multi-speed control input 4
10: Acceleration/deceleration time 1 activation
11: Acceleration/deceleration time 2 activation
12: Acceleration/deceleration time 3 activation
15: Freewheeling stop activation
16: Stop DC-braking activation
20: Frequency Up command
21: Frequency Down command
22: Up/Down command reset
23: Torque/Speed control switch
25: 3-wire control
26: Simple PLC stop
27: Simple PLC pause
30: Second frequency setting source activation
31: Second run command source activation
32: Error signal N.O. contact input
33: Error signal N.C. contact input
34: Error reset
35: Forward running (FWD)
36: Reverse running (REV)