SP1xxx: Feed
D017/D018/D019/D020 5-16 SM
1 Roller Center
2 Roller Ends
Displays the fusing temperature for the center or
both ends of the hot roller.
3
In the Machine at Power
On
Displays the temperature in the machine at
power on.
This temperature is monitored by the thermistor
on the SBCU board.
Fusing Soft Start Adj: Cycle
1108*
Selects whether the fusing temperature control cycle is 1 or 3 seconds.
If this is “1 (3 s)”, the power supply fluctuation caused by the fusing lamp
turning on is less often.
[0 = 1 s / 1 = 2 s]
Default: 0 = N. America, Taiwan, 1 = Europe/Asia
Fusing Nip Band Check
1109*
Checks the fusing nip band.
1 Execution
Idling Rotation Time
[0 to 120 / 60 / 1 sec]
2
Specifies the fusing rotation time before executing SP1109-001.
Pre-Idling Time
[5 to 30 / 10 / 1 sec]
3
Specifies the time that the paper stops in the fusing unit for measuring the
nip.
Fusing Jam Detection
1159
Disables or enables the consecutive jam error for the fusing unit.
[0 to 1/0/1 Step]
When set to "1" (on) this SC code is issued after the 3rd consecutive jam in
the fusing unit.