HDD Encryption Unit
SM 1-73 D017/D018/D019/D020
Installation
1.20 HDD ENCRYPTION UNIT
1.20.1 INSTALLATION
Seal Check and Removal
1. Check the box seals [1] on each corner of the box.
Make sure that a tape is attached to each corner.
The surfaces of the tapes must be blank. If you see “VOID” on the tapes, do not
install the components in the box.
2. If the surfaces of the tapes do not show “VOID”, remove them from the corners of the
box.
3. When you remove each seal, the “VOID” marks [2] can be seen. In this condition, they
cannot be reattached to the box.
Installation Procedure
1. Make sure that the following settings are not at the factory default settings:
Supervisor login password
Administrator login name
Administrator login password
These settings must be set up by the customer before the encryption option
can be installed.