Bridge Unit (D368)
D017/D018/D019/D020 1-44 SM
1.11.2 INSTALLATION PROCEDURE
Unplug the copier power cord before starting the following procedure.
1. Remove all tapes.
2. Loosen the screw [A] and remove the front right cover [B].
3. If the sensor feeler [C] is out, fold it away into the machine.
4. Remove the cover [A].
5. Install the bridge unit [B] (1 shoulder screw, 1 knob screw).
6. Reinstall the front right cover [C].
7. Connect the cable [D] to the main machine.
8. Attach the securing plate [E], as shown.
Do not attach it with a screw; This is done when securing the front stand for
the optional finisher.
9. Install the optional finisher (refer to the finisher installation procedure).