Scanning
D017/D018/D019/D020 6-20 SM
6.4.3 ORIGINAL SIZE DETECTION
The original width sensors [A] detect the original width. The original length sensors [B]
detect the original length.
The SBU controller on the SBU board checks each sensor status when the platen
cover sensor [C] is activated as it is closed. It detects the original size by the on/off
signals it gets from each sensor.
If the copy is made with the platen cover fully open, the SBU controller on the SBU
determines the original size from the sensor outputs after the Start key is pressed.