SP2xxx: Drum 
SM 5-33 D017/D018/D019/D020 
Service 
Tables 
 
Toner Recovery Time 
2923* 
Adjusts the toner supply motor on time during recovery from toner 
near-end/end. 
This SP is effective only when SP2921 is “0”, “1”, or “2”. 
[1 to 60 / 30 / 1 s/step] 
Note that toner recovery is done in a 3-second cycle. So, the input value 
should be a multiple of 3 (e.g. 3, 6, 9). See “Toner Density Control” for more 
details. 
 
Toner Supply Ratio 
2925* 
Adjusts the toner supply rate for fixed toner supply mode. 
This SP is effective only when SP2921 is “2” or “3”. 
Increasing this value increases the toner supply motor on time. So, use a 
high value if the user tends to make lots of copies that have a high 
proportion of black. See “Toner Density Control” for more details. 
[0 to 7 / 0 / 1/step] 
0: t, 1: 2t, 2: 4t, 3: 8t, 4: 12t, 5: 16t, 6: On continuously, 7: 0 s 
t: 200 ms 
 
Standard Vt DFU 
2926* 
Adjusts Vts (Vt for a new PCU). The TD sensor output is adjusted to this 
value during the TD sensor initial setting process. This SP is effective only 
when SP2921 is “0”, “1”, or “2”. 
[0.00 to 5.00 / 2.50 / 0.05 V/step] 
 
ID Sensor Control 
2927* 
Selects whether the ID sensor is used or not for toner density control. 
[0 = No / 1 = Yes] 
If this value is “0”, dirty background may occur after the machine has not 
been used for a long time.