SP4xxx: Scanner
SM 5-49 D017/D018/D019/D020
Service
Tables
0: Not activated
Note: This SP code exists for SP4580, SP4582 and
SP4583 only.
SBU Version
4600
Displays the version number of the SBU.
4602 Scanner Memory Erase
1 Scanner Memory Access
Enables the read and write check for the
SBU registers.
2 Address Setting
3 Data Set
Not used.
AGC Execution DFU
4603
Executes the AGC.
1 HP Detection Enable
2 HP Detection Disable
FGATE Open/Close
4604
Opens or closes the FGATE signal. This SP automatically returns to the
default status (close) after exiting this SP.
[0 or 1 / 0 / 1/step]
0: OFF, 1: ON
Note:
When the registration sensor goes ON, the BCU generates the FGATE
signal and sends it to the LD units.
As soon as the LD units receive the FGATE signal, they send a
feedback signal to the BCU.
SC230, SC231 if the FGATE signal fails to switch on or off.