SP7xxx: Data Log
SM 5-165 D017/D018/D019/D020
Service
Tables
Resets the SC and jam counters. To reset, press Execute on the touch
panel.
This SP does not reset the jam history counters: SP7507, SP7508.
MF Error Counter Japan Only
7826
Displays the number of counts requested of the card/key counter.
1 Error Total
A request for the count total failed at power on. This error
will occur if the device is installed but disconnected.
2 Error Staple
The request for a staple count failed at power on. This error
will occur if the device is installed but disconnected.
MF Error Counter Clear Japan Only
7827
Press Execute to reset to 0 the values of SP7826. Japan Only
Self-Diagnose Result Display
7832
Execute to open the “Self-Diagnostics Result Display” to view details about
errors. Use the keys in the display on the touch-panel to scroll through all
the information. If no errors have occurred, you will see the “No Error”
message on the screen.
Coverage Data Clear
7834
These SPs clear the counters for the following items.
1 Last & Average
2 No. of Toner Bottles
3 Page Count: Bottle
4 Dot Coverage Clear
255 All Coverage Data