Bypass Feed Unit (D370)
SM 1-37 D017/D018/D019/D020
Installation
1. Remove all tapes.
2. Remove the entrance cover [A] ( x 2) and cover [B] ( x 2).
These removed screws will be used in steps 3 and 5.
3. Install the by-pass tray unit [A] ( x 4: two of these are removed in Step 2).
4. Connect the cable [B] to the machine.
5. Install the connector cover [C] ( x 1: this screw is removed in Step 2).
6. Open the right cover [A].
7. Release the rear link [B] ( x 1).