NCU Parameters
SM 139 D361
Fax Option
Type 3350
D361
Address Function Unit Remarks
Bit 1 Bit 0 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 2 and 3 - Handset on-hook detection time
Bit 3 Bit 2 Setting
0 0 200 ms
0 1 800 ms
Other Not used
Bits 4 to 7 - Not used
680583
to
6805A0
Not used
Do not change the
settings.
6805A1
Acceptable CED detection frequency
upper limit (high byte)
6805A2
Acceptable CED detection frequency
upper limit (low byte)
BCD (Hz)
If both addresses
contain FF(H), tone
detection is disabled.
6805A3
Acceptable CED detection frequency
lower limit (high byte)
6805A4
Acceptable CED detection frequency
lower limit (low byte)
BCD (Hz)
If both addresses
contain FF(H), tone
detection is disabled.
6805A5 CED detection time
20 ms
± 20 ms
Factory setting: 200 ms
6805A6
Acceptable CNG detection frequency
upper limit (high byte)
BCD (Hz)
If both addresses
contain FF(H), tone