1-106-002 RollerEnds E
[-20 to 250 / 0 / 1deg/step]
Displays the current fusing thermistor
temperature (Ends).
1-106-003 MachinePowerOn E
[-20 to 250 / 0 / 1deg/step]
Displays the external temperature measured
at power On, which is detected with the
temperature and humidity sensor.
1109
[Micro Ptcl SW]
The switch that turns ON/OFF the micro particle countermeasure mode.
1-109-001 0:Off 1:On E [0 or 1 / 0 / 1 / -]
1113 [Env Fus Cond]
1-113-001 PrePrtRotTime E [500 to 60000 / 7000 / 500msec/step]
1135
[Inrush Control]
Enables or disables the setting of Inrush control (0: Disabled, 1: Enabled)
1-135-001 Inrush control E [0 or 1 / 0 / 1 /step]
1152
[Nip Width Measuring]
Checks the fusing nip band.
1-152-001 0:Off 1:On E [0 or 1 / 0 / 1 /step]
1159
[Fusing Jam Detect]
Disables or enables the consecutive jam error for the fusing unit.
When set to "1" (on) this SC code is issued after the 3rd consecutive jam in the fusing
unit.
1-152-001 SCdisplay E
[0 or 1 / 0 / 1 /step]
0: Not detects SC
1: Detects SC