Bit Switches
SM 119 D361
Fax Option
Type 3350
D361
G3-2 Switch 07 (SP No. 1-106-008)
No Function Comments
0: Disabled
1: Enabled
5-7 Not used Do not change the settings.
G3-2 Switch 08 - Not used (do not change the settings)
G3-2 Switch 09 - Not used (do not change the settings)
G3-2 Switch 0A (SP No. 1-106-011)
No Function Comments
Maximum allowable carrier drop
during image data reception
Bit 1 Bit 0 Value (ms)
0 0 200
0 1 400
1 0 800
0-1
1 1 Not used
These bits set the acceptable modem
carrier drop time.
Try a longer setting if error code 0-22 is
frequent.
2
Select cancellation of high-speed RX
if carrier signal lost while receiving
0: Off
1: On
This switch setting determines if
high-speed receiving ends if the carrier
signal is lost when receiving during
non-ECM mode
3 Not used Do not change the settings
4
Maximum allowable frame interval
during image data reception.
0: 5 s 1: 13 s
This bit set the maximum interval
between EOL (end-of-line) signals and
the maximum interval between ECM
frames from the other end.