Bit Switches
D361 128 SM
IP Fax Switch 08 (SP No. 1-111-009)
No. Function Comments
T1 timer adjustment
Bit 1 Bit 0
0 0 35 s
0 1 40 s
1 0 50 s
0-1
1 1 60 s
Adjusts the T1 timer.
The default is "00" (35 seconds).
T4 timer adjustment
Bit 3 Bit 2
0 0 3 s
0 1 3.5 s
1 0 4 s
2-3
1 1 5 s
Adjust the T4 timer.
The default is "00" (3 seconds).
T0 timer adjustment
Bit 5 Bit 4
0 0 75 s
0 1 120 s
1 0 180 s
4-5
1 1 240 s
Adjusts the fail safe timer. This timer sets
the interval between "setup" data
transmission and T.38 phase decision. If
your destination return is late on the
network or G3 fax return is late, adjust the
longer interval timer.
The default is "00" (75 seconds).
6-7 Not used Do not change these settings.