Service Call Conditions 
M018/M019 3-18 SM Appendix 
3.2.3 CONTROLLER SC 
SC8xx 
 
Service Cycle Power 
  Incorrect combination of EGB and controller board.   
  An unexpected error occurs in the EEPROM on the controller board. 
819 
  Controller board defective 
1.  Install the correct EGB and controller boards for this machine. 
2.  Replace the controller board 
 
USB/ Network Device Error 
An interface error in the USB connection or NIB connection occurs. 
823 
  Controller board detective 
1. Replace the controller board. 
 
EEPROM Error 
An EEPROM check error at power-on occurs. 
824 
  Controller board detective 
1. Replace the controller board. 
 
On-Board Memory Check Error 
An on-board memory check error at power-on occurs.   
827 
  Controller board detective 
1. Replace the controller board. 
 
http://www.manuals4you.com