Electrical Components 
SM 4-59 M018/M019 
Replacement 
& 
Adjustment 
 
 
  The default setting is "OFF". Select "ON" only if the customer wants to use this 
feature. 
17.  Select "Registration", and then adjust the registration for each direction (vertical and 
horizontal direction) and tray if necessary.   
18.  Select "2nd Transfer Fuser Temp", and then adjust the transfer roller bias and the 
temperature reduction of the fusing unit for each paper type and for the front and back 
sides. The default settings for normal operation are all '0'. 
19.  Exit "Engine Maintenance". 
PnP Name (Plug and Play) Procedure 
Set the PnP name as follows when replacing the EEPROM of the MF version. 
0xAB 
A indicates the brand. B indicates the model. 
A: Brand 
Brand 0 1  2  3 4 5 6 7 
Name  Not used RICOH  Gestetner Not used LANIER NRG  Savin  Generic
B: Model 
Brand    Ricoh: 1 
Gestetner,  LANIER, 
NRG, Savin: A= 2, 4, 5, 
or 6 
Generic:7 
Model  0x00 0x11 0x12  0x13 
0x
A4 
0xA5  0xA6  0x77  0x78  0x79 
Name 
not 
used 
not 
used
Aficio 
SP 
C231SF 
Aficio 
SP 
C232SF
not 
used
SP 
C231SF
SP 
C232SF
not 
used
C231SF C232SF
Brand ID: 0x01 (default) 
This ID is not related to the PnP Brand name. Do not change the setting; otherwise, a 
malfunction may occur. 
Maintenance ID: 0x00 (default) 
Do not change the setting; otherwise, a malfunction may occur. 
LSU Adjustment 
Input the data using the number keys. The cursor can be moved to the right or the left with 
the Down arrow or the Up arrow keys. You can change the alphanumeric characters by 
repeatedly pressing the number keys (like a mobile phone). (Example: 2 Æ a Æ b Æ c) 
There is no “back space” function. If you input incorrect data, you have to delete all the data 
input by pressing the Clear/Stop key. Then, input the LSU data again. 
Rev. 02/03/2010 
⇒