Service Menu
M018/M019 4-10 SM Appendix
Fax Maintenance
Silence
Detection Time
Silence (No tone) detection time (Rx mode : FAX/
TAD Only)
After the line is connected via the external
telephone, the machine can detect silence (no
tone) for the time length specified by this setting.
[30 sec (Default)]
CNG Tone
Detection Time
CNG tone detection time ( RX mode : FAX / TEL,
FAX / TAD Only)
After the line is connected via the external
telephone, the machine can detect a CNG signal
for the time length specified by this setting.
[5 Sec (Default)/ 10 Sec]
CNG Cycles
Number of CNG cycles to be detected
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]
Tone Sound
Monitoring
Determines the period when tones from the line
are monitored.
[No Monitoring/ Up To Phase B (Default)/ All TX
Phases]
Stop/Clear key
Pressing the Stop/Clear key can stop the current
receiving operation. Received data is lost.
[Not Functional (Default)/ Functional]
RX Settings
Off-Hook Level
Sets the off-hook detection threshold.
[10V (Default)/ 15V/ 20V/ 25V]
Redial Interval
Sets the redial interval when Tx fails.
[5 Min/ 6 Min]
TX Settings
Redialings
Sets the number of redials when Tx fails.
[2 times/ 3 Times/ 4 Times/ 5 Times]
http://www.manuals4you.com