1. After setting up the system, do a folding test run with at least 10 sheets of A1 LEF paper.
Before doing this procedure, measure the distances between the bridge unit and the left and
right rear corners of the main machine. The difference between these two distances must not be
more than 1 mm.
2. Measure the amount of skew.
If the average amount of skew is less than ±0.5 mm, no adjustment is required.
If the average amount of skew is more than ±0.5 mm, adjustment is required.
3. Do the adjustment:
For Adjust: Turn plate:
A Right side Right (cw)
B Right side Left (ccw)
In the table above, "cw" means "clockwise", "ccw" means "counter-clockwise".
The range of adjustment is ±1.5 mm within an arc of 90 degrees (±0.75 mm if rotated only 45
degrees.)
4. To determine the amount of adjustment, divide the amount of measured skew (mm) by 0.0166 mm.
Refer to the detailed instructions below.