When line thickness more than 2 dots the value selected for SP2954-10 affects only the outer lines. The
diagram above shows "1" selected for SP2954-10. The setting does not affect the horizontal line.
2955 Binary Smoothing: Print
This SP controls the number of times that binary smoothing is performed.
1 2 Times
This SP switches double-smoothing ON/OFF
[0 to 2/2/1] [0 to 2/2/1]
2 3 Times
This SP switches triple-smoothing ON/OFF
[0 to 2/2/1]
2959
VDB ID
Reads and displays the FPGA version 8-bit data of the VDB.
Note: The VDB (Video Drive Board) controls the LPH. It processes the image information sent
from the IPU and sends it to the LPH.
SP3000 Process Control
3001 ID Sensor Initial Setting
1
PWM Setting: ID Sensor LED
Adjusts PWM. DFU
[0 to 100/20/0.01%]
2
Initialization
Automatically adjusts the output to 4.0 ±0.2V. During auto adjustment, the voltage applied to
the ID Sensor LED depends on the PWM value.
Press the Start button to initialize the ID sensor LED with the value entered for the PWM.
Initialization requires about 4 seconds.
Note: Do this SP cleaning the ID sensor and after replacement of the drum, ID sensor, NVRAM
and BCU.
3103
ID Sensor Output Display
8. Appendix: SP Mode Tables