Configuration 4: Main Machine + Scanner Separation Unit Type 7140 (D436)
Machine Level
1. Front to back: Within 0.15 mm/1000 mm (0.006”/39.4”) of level
2. Right to left: Within 0.15 mm/1000 mm (0.006”/39.4”) of level. Make sure that the machine is level
using a carpenter’s level.
Power Source
The machines must be installed in a building or facility equipped with a protective device such as a circuit
breaker, as the machine relies on such devices for protection against over-current and short circuits
Main Machine (D046/D049)
1. Input Voltage Level:
200V, 60Hz, More than 15 A (for the U.S.A. version)
220 to 240V, 50/60Hz, More than 15 A (for the Europe/China version)
Preparation