• Do these adjustments in the order prescribed below.
(1)
Printer Skew Adjustment
SP1914-2, -3 (Fusing Pressure Adjustment)
Standard: No more than 1 mm skew /1 m.
Note: Difference between the two SP values must be less than 30.
(2)
Printer Magnification Adjustment
Standard: Magnification error less than ±0.3%.
(3)
Print and Erase Margin Setting
SP4012-5, -7 (Scanner Erase Margin): 0
SP2101-1, -3 (Print Erase Margin): 5 mm
(4)
Printer Leading Edge and Side-to-Side Registration
SP1001 (Leading Edge Registration)
Standard: 5±2.8 mm.
SP1002 (Side-to-side Registration)
Standard: 5±2.0 mm
(5)
Restoring the Printing and Scanner Erase Margin Setting
SP4012 (Scanner Erase Margin)
SP2101 (Printing Erase Margin)
Return to previous setting (before Step 3)
(6)
Printer/Scanner Magnification
SP4101 001 (Scanner Main Scan Mag.)
SP4008 001 (Scanner Sub Scan Mag.).
Standard: Magnification error less than ±0.5%
(7)
Printer/Scanner Leading Edge Registration
SP4010 001 (Scanner Sub Scan Registration)
Standard: ±3.0 mm
(8)
Printer/Scanner Side-to-side Registration
SP4011 (Scanner Main Scan Registration)
Standard: ±2.8 mm
4. Replacement and Adjustment