An error not controlled by the system occurred (the error does not come under any
other SC code).
Software defective
Turn the machine power off and on. The machine cannot be used until this error
is corrected.
SC994 C
Operation panel management code error GW
Thee number of records exceeded the limit for images managed in the service layer
of the firmware. This can occur if there are too many application screens open on
the operation panel.
No action required.
This error does not interfere with operation of the machine.
SC997 B
Software Error 4: Cannot select application function GW
An application does not start after the user pushed the correct key on the operation
panel.
Software bug
A RAM or DIMM option necessary for the application is not installed or not
installed correctly.
SC998 D
Software Error 5: Application cannot start GW
Register processing does not operate for an application within 60 s after the machine
power is turned on. No applications start correctly, and all end abnormally.
Software bug
A RAM or DIMM option necessary for the application is not installed or not
installed correctly.