light emitted from left TM/P sensor after
Vsg adjustment succeeded.
[0.10 to 7.5 / 4.78 / 0.01g/m
2
]
Sets for Image Retry Function.
[0 (Disable) / 1 (Enable)]
Sets whether to display the PM parts
replacement notice and whether to stop
the engine.
[0 to 3 / 2 / 1/step]
• 0: At near end: No notice, At life end:
Notice “Replace Now”
• 1: At near end: No notice, At life end:
No notice
• 2: At near end: Notice, At life end:
Notice “Replace Now”
• 3: At near end: Notice, At life end:
Notice “Replace Now” and machine
stop
Determines the maximum amount of
toner you can use in any area of your
text.
[Off, 200 to 400 / 250 / 10/step]
Determines the maximum amount of
toner you can use in any area of your
graphic.
[Off, 200 to 400 / 250 / 10/step]
Determines the maximum amount of
toner you can use in any area of your
image.
[Off, 200 to 400 / 250 / 10/step]