5.8 Automac control (ACS) (24 V AC/DC)
You can connect the RLL400 control-unit to an automac control system (ACS). Refer to the diagram
that follows and connect the ACS. Also refer to the product manual of the ACS that is used.
Notes:
• When the two inputs of the digital control (pin 1 and 3) receive a control signal at the same me,
the control unit will not process them. The electric motor does not move.
• The external power supply can be 24 V AC/DC.
• Refer to §3.5 for the technical specicaons of the external power supply of connector X6.
Connector X6 of the control board (A2) can be connected to
automac control systems (ACS) that have a “switched ground” or a
“switched posive”.
5.9 OPTIONAL - Manual control (MC)
You can connect the RLL400 control-unit to a manual control (MC) such as the Ridder MC Module
Compact (277950).
• Remove the jumper from connecon 1 and 3 of X8.
• Connect the manual control (MC). Refer to the diagram that follows.
Refer to the related manual when you connect a dierent manual control (MC).
Control board A2
Control board A2
YES NO
MC
Ridder Drive Systems B.V.
T +31 (0)341 416 854 - F +31 (0)341 416 611 - I ridder.com
18