5.8 Automac control (ACS) (24 V AC/DC)
You can connect the RLL400 control-unit to an automac control system (ACS). Refer to the diagram
that follows and connect the ACS. Also refer to the product manual of the ACS that is used.
Notes:
When the two inputs of the digital control (pin 1 and 3) receive a control signal at the same me,
the control unit will not process them. The electric motor does not move.
The external power supply can be 24 V AC/DC.
Refer to §3.5 for the technical specicaons of the external power supply of connector X6.
Connector X6 of the control board (A2) can be connected to
automac control systems (ACS) that have a “switched ground” or a
“switched posive”.
5.9 OPTIONAL - Manual control (MC)
You can connect the RLL400 control-unit to a manual control (MC) such as the Ridder MC Module
Compact (277950).
Remove the jumper from connecon 1 and 3 of X8.
Connect the manual control (MC). Refer to the diagram that follows.
Refer to the related manual when you connect a dierent manual control (MC).
Control board A2
Control board A2
YES NO
MC
Ridder Drive Systems B.V.
T +31 (0)341 416 854 - F +31 (0)341 416 611 - I ridder.com
18