- 87 - GD-70D
Detection Gas
Range
Calibration Instructions
Br2 (Bromine) 0 - 1.00 ppm Calibrating with a Surrogate Gas (Sensors with Factors) on
page 93
BTBAS (Bis[tertiary-butyl-
amino]silane)
0 - 15.0 ppm Calibrating with a Surrogate Gas (Sensors with Factors) on
page 93
C2H2 (Acetylene) 0 - 2,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
C2H2Cl2 (Dichloroethene) 0 - 600 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
C2H4 (Ethylene)
0 - 2,000 ppm
Calibrating with a Humidifier (MOS Sensors) on page 103
C2H5OH (Ethanol) 0 - 2,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
C3H6 (Propylene) 0 - 5,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
C3H8 (Propane) 0 - 2,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
0 - 5,000 ppm
0 - 100% LEL Calibrating with on page 90
C4F6 (Hexafluorabutadiene) 0 - 200 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
C4H10 (Isobutane) 0 - 100 %LEL Calibrating with a Demand Flow Regulator on page 90
C6H14 (Hexane) 0 - 2,000 ppm Calibrating with on page 90
CH2Cl2 (Dichloromethane) 0 - 2,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
CH3CN (Acetonitrile) 0 - 2,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
CH3COOH (Acetic acid) 0 - 30.0 ppm Calibrating with a Surrogate Gas (Sensors with Factors) on
page 93
CH3NH2 (Methylamine) 0 - 15.0 ppm Calibrating with a Surrogate Gas (Sensors with Factors) on
page 93
CH3OH (Methanol) 0 - 1,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
0 - 2,000 ppm
CH4 (Methane) 0 - 100 %LEL Calibrating with a Demand Flow Regulator on page 90
0 - 2% vol Calibrating with a Humidifier (MOS Sensors) on page 103
0 - 2000 ppm
0 - 5000 ppm
CH6Si (Methyl silane) 0 - 20.0 ppm Calibrating with a Surrogate Gas (Sensors with Factors) on
page 93
Cl2 (Chlorine) 0 - 3.00 ppm Calibrating with a Demand Flow Regulator on page 90
ClF3 (Chlorine trifluoride) 0 - 0.60 ppm Calibrating with a Surrogate Gas (Sensors with Factors) on
page 93
CO (Carbon monoxide) 0 - 75.0 ppm Calibrating with a Demand Flow Regulator on page 90
0 - 150 ppm
0 - 300 ppm
COS (Carbonyl sulfide) 0 - 2,000 ppm Calibrating with a Humidifier (MOS Sensors) on page 103
0 - 90.0 ppm Calibrating a Pyrolyzer Unit on page 107

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKI Instruments GD-70D Series and is the answer not in the manual?

RKI Instruments GD-70D Series Specifications

General IconGeneral
BrandRKI Instruments
ModelGD-70D Series
CategoryGas Detectors
LanguageEnglish

Related product manuals