33
Maximum NonRes. - A maximum temperature of the LED PCB since the xture has been
fabricated.
Maximum Res. - A maximum temperature of the LED PCBs since the counter
was last reset.
In order to reset some counter to 0, touch desired text box under item "Max.Res."
Driver Temperature - The menu shows temperature on the LEDs control PCB in the xture head.
Current - A current temperature on the LEDs control PCB.
Maximum NonRes. - A maximum temperature on the LEDs control PCB since
the xture has been fabricated.
Maximum Res. - A maximum temperature on the LEDs control PCB since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res.
PSU Temperature - The menu shows temperature of power supply unit in the xture base.
Current - A current temperature of power supply unit.
Maximum NonRes. - A maximum temperature of power supply unit since the xture
has been fabricated.
Maximum Res. - A maximum temperature of power supply unit since the counter was
last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res.
Note: There are two power supply units in the xture base, temperature is measured on each power supply
unit but displayed is only one value (higher measured value).
Base Temperature - The menu shows temperature on the display PCB in the xture base.
Current - A current temperature on the display PCB.
Maximum NonRes. - A maximum temperature on the display PCB since the xture has
been fabricated.
Maximum Res. - A maximum temperature on the display PCB since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
RAINS Status - The menu item gives you information about environment in the xture.
RAINS (Robe Automatic Ingress Neutralization System) manages humidity, temperature and pressure control
using an active monitoring system to automatically remove any moisture detected within the xture and provides
permanent monitoring to ensure peak performance of the xture.
The bar chart Actual informs you about current humidity in the xture. The bar chart changes depending on
humidity, temperature and pressure in the xture. The bar chart depends on current conditions in the xture and
can be di󰀨erent at start of xture operation, after 10 minutes of its operating, after closing xture dimmer etc.
The bar chart MAX WET informs you about maximum humidity achieved in the xture since the chart was last
reset. The bar chart also informs you about saturation of silica gel desiccants in the xture arm with water and
is deciding indicator for their checking and replacement.
The option MAX WET reset resets the bar chart MAX WET. Date and time of last reset is displayed below the
option.
Silica gel desiccants
in the xture arm