47
Fr. Shutter 2 Error 1
Impact to the mechanical end of the framing shutter 2 was not detected.
Fr. Shutter 2 Error 4
Incorrect detection of the framing shutter 2. Impact to a mechanical obstruction was detected within running of
the framing shutter 2.
Fr. Shutter 3 Error 1
Impact to the mechanical end of the framing shutter 3 was not detected.
Fr. Shutter 3 Error 4
Incorrect detection of the framing shutter 3. Impact to a mechanical obstruction was detected within running of
the framing shutter 3.
Fr. Shutter 4 Error 1
Impact to the mechanical end of the framing shutter 4 was not detected.
Fr. Shutter 4 Error 4
Incorrect detection of the framing shutter 4. Impact to a mechanical obstruction was detected within running of
the framing shutter 4.
EEprom Error
Hardware error of the EEprom.
Recharge The battery
The battery on the display board needs to be charged. Let the xture on for cca 6 hrs.
Battery Faulty. Replace it.
The battery on the display board is exhausted and should be replaced immediately.
Pan/Tilt EMS Cal. Error
The EMS system is not calibrated.
Pan/Tilt EMS Error
Control electronics cannot communicate with the EMS system.
Internal Error 1
Communication error between PCBs (error or noise was detected on communication wires)
Internal Error 2
Communication error (some PCB has failed or is disconnected (this PCB will show as N/A in menu --> Infor-
mation --> Software versions) or error/noise was detected on communication wires)
Overheated
The LED engine is overheated and light output is closed.
Temperature Sensor Error
Some of temperature sensor in xture head (LEDs or driver) is faulty.
White 1 Short Error (White 2 Short Error/ White 3 Short Error/ White 4 Short Error)
Some white LEDs in the light source have short circuit.
White 5 Short Error (White 6 Short Error/ White 7 Short Error/ White 8 Short Error)
Some white LEDs in the light source are disconnected.
Too Much Humidity in Device
To remove the message, reset the bar chart Max.Wet in the menu RAINS Status (tab Information) and check
the silica gel desiccants in the xture arm.
Valve Seal Error
The valve in xture arm or coil in the valve is defective or there is a connection problem
between the valve and
head, check cable connector at valve.