Rockwell Automation Publication 1794-UM061B-EN-P - March 2020 91
Configure your Digital Module on an EtherNet/IP Network Chapter 7
Add a Module
The Comm Format selection that you make when you add a communication
module and its I/O modules is based on whether you want rack-optimized or
direct connections to each distributed I/O module. In general:
Download the Program to
the Controller
Follow this procedure to download the program you saved to the ControlLogix
controller.
1. From the main menu, choose Communication>Who-Active.
2. Select the processor slot in the chassis.
3. From the Who-Active dialog, choose Set Project Path.
To Do this
Use the default
configuration
Specify the general
information about the module
(name, comm format, and so
on) and click Finish.
Customize the
configuration
Specify the general
information about the module
(name, comm format, and so
on). Then use the tabs to step
through subsequent screens.
1. Right-click the level (branch) to which you want to
add the module and choose New Module.
2. Choose the module.
3. Configure the module.
If the distributed I/O is Select this format for the remote
adapter
Select this format for the distributed
I/O module
Digital Rack Optimization Rack Optimization
Analog None An appropriate direct-connection format.