This chapter lists important information the reader should consider before starting to
build the system. It includes preparatory information necessary for a successful
installation.
In This Chapter
In This ChapterIn This Chapter
In This Chapter
Required Tools Standard AADvance ............................................................. 2-1
Test Equipment ................................................................................................... 2-2
System Installation Environment ..................................................................... 2-2
Specifying an Enclosure...................................................................................... 2-2
Controller Design Considerations for Heat and Cooling ........................ 2-7
System Power Requirements ........................................................................... 2-7
Power Arrangements for Field Devices ........................................................ 2-9
Estimate Module Supply Power Dissipation and Field Loop Power
Dissipation ............................................................................................................ 2-9
Estimate AADvance Controller Weight ..................................................... 2-10
Estimating Centre of Gravity Information .................................................. 2-10
Design Considerations for Electrical Grounding ...................................... 2-11
Power Supply Requirements .......................................................................... 2-11
Specifying the Workstation PC ..................................................................... 2-12
Design Considerations for Maintenance Activities
................................
...
2
-
12
Required Tools Standard AADvance
Required Tools Standard AADvanceRequired Tools Standard AADvance
Required Tools Standard AADvance
The installation and maintenance of the AADvance controller requires the following
tools:
Stand
StandStand
Standard Tools
ard Toolsard Tools
ard Tools
Screwdriver, flat 0.8 x 9.0mm (1/25 c 3/8 inch), for the module clamp screws and
blanking covers
Screwdriver, cross head number 0, for battery cover on T9110 processor module
screwdriver, flat 0.8 x 4.0mm (1/25 x 5/32 inch), for locking screws on extension
cables
Torque screwdriver, flat 0.6 x 3.0 mm(1/40 x 1/8 inch, for dc power wiring
terminals
Torque screwdriver, flat 0.4 x 2.0mm (1/64 x 5/64), for field wiring terminals
2 x wrench, open end, 10mm, for ground stud nuts
Allen key (hex wrench), 2.5mm, for plug and sockets assemblies used with
extension cables
Special Tool
Special ToolSpecial Tool
Special Tool
Long nosed pliers to remove the fuses on termination assemblies.
Chapter
Chapter Chapter
Chapter
2
22
2
Before You Begin
Before You BeginBefore You Begin
Before You Begin

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation ics triplex AADvance and is the answer not in the manual?

Rockwell Automation ics triplex AADvance Specifications

General IconGeneral
BrandRockwell Automation
Modelics triplex AADvance
CategoryController
LanguageEnglish

Related product manuals