FORMat Subsystem FSE
1065.6016.12 6.118 E-16
:FORMat:DEXPort:DSEParator POINt|COMMa
This command determines the decimal separator (decimal point or comma)for the output of the
measurement data in ASCII format. Thus, evaluation programms (i.e. MS-Exel) of different language
versions are supported.
Example: ":FORM:DEXP:DSEP POIN
Features: *RST value: POINt
SCPI: device specific
Modes: A, VA, BTS, MS
:FORMat:DEXPort:HEADer[:STATe] ON | OFF
This commad determines if the output file starts with a header (start frequency, sweep time, detector,
.. = ON) or not. OFF = only measurement data is output.
Example: ":FORM:DEXP:HEAD OFF
Features: *RST value: ON
SCPI: device specific
Modes: A, VA, BTS, MS
:FORMat:DEXPort:APPend[:STATe] ON | OFF
This commad determines if the output file is overwritten or the data is added to the end of the file.
Example: ":FORM:DEXP:APP OFF
Features: *RSTvalue: ON
SCPI: device-specific
Modes: A, VA, BTS, MS
:FORMat:DEXPort:COMMent <string>
This command defines a comment for the output file.
Example: ":FORM:DEXP:COMM ASCII EXPORT TRACE 1’"
Features: *RST value: „“
SCPI: conforming
Modes: A, VA, BTS, MS