FSE SENSe Subsystem
1065.6016.12 6.193 E-16
SENSe:FREQuency Subsystem
The SENSe:FREQuency subsystem defines the frequency axis of the active display. The frequency axis
can either be defined via the start/stop frequency or via the center frequency and span.
COMMAND PARAMETERS UNIT COMMENT
[SENSe<1|2>]
:FREQuency
:CENTer
:LINK
:STEP
:LINK
:FACTor
:SPAN
:FULL
:LINK
:STARt
:LINK
:STOP
:LINK
:MODE
:OFFSet
<numeric_value>
STARt | STOP | SPAN
<numeric_value>
SPAN | RBW | OFF
<numeric_value>
<numeric value>
--
CENTer | STARt | STOP
<numeric_value>
CENTer | STOP | SPAN
<numeric_value>
CENTer | STARt |SPAN
CW | FIXed | SWEep
<numeric_value>
HZ
--
HZ
--
PCT
HZ
--
--
HZ
--
HZ
--
--
HZ
:[SENSe<1|2>:]FREQuency:CENTer 0 GHz to f
max
This command defines the center frequency of the analyzer.
Example: ":FREQ:CENT 100MHz"
Features: *RST value: f
max
/ 2
SCPI: conforming
Modes: A, VA, MS, BTS
The automatic coupling of the parameters is set to SPAN FIXED.
:[SENSe<1|2>:]FREQuency:CENTer:LINK STARt | STOP | SPAN
This command defines the coupling of the center frequency to the start, stop frequency or the
frequency span.
Example: ":FREQ:CENT:LINK STAR"
Features: *RST value: SPAN
SCPI: device-specific
Mode: A
:[SENSe<1|2>:]FREQuency:CENTer:STEP 0 to f
max
This command defines the step width of the center frequency.
Example: ":FREQ:CENT:STEP 120MHz"
Features: *RST value: - (AUTO 0.1 × SPAN is switched on)
SCPI: conforming
Modes: A, VA, BTS, MS