EasyManua.ls Logo

Rohde & Schwarz FSEA20 - Sense:filter Subsystem

Rohde & Schwarz FSEA20
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SENSe Subsystem FSE
1065.6016.12 6.190 E-16
SENSe:FILTer Subsystem
The SENSe:FILTer subsystem selects the filters in the video signal path.This subsystem is active only in
the Vector Signal Analysis mode (option FSE-B7).
COMMAND PARAMETERS UNIT COMMENT
[SENSe<1|2>]
:FILTer
:HPASs
[:STATe]
:FREQuency
<Boolean>
<numeric_value>
--
HZ
Vector Signal Analyzer
:LPASs
[:STATe]
:FREQuency
:CCITt
[:STATe]
:CMESsage
[:STATe]
:DEMPhasis
[:STATe]
:TCONstant
:LINK
<Boolean>
<numeric_value>
<Boolean>
<Boolean>
<Boolean>
<numeric_value>
DISPlay | AUDio
--
HZ | PCT
--
--
S
Vector Signal Analyzer
:[SENSe<1|2>:]FILTer:HPASs[:STATe] ON | OFF
This command activates the high-pass filter in the AF-branch for analog demodulation.
Example: ":FILT:HPAS ON"
Features: *RST value: OFF
SCPI: conforming
Mode: VA-A
:[SENSe<1|2>:]FILTer:HPASs:FREQuency 30 Hz | 300 Hz
In the Vector Signal Analysis mode with analog demodulation, this command defines the frequency
limit of the high-pass filter in the AF-branch. For REAL TIME ON absolute frequencies are entered,
for REAL TIME OFF, the frequencies are entered relative to the demodulation bandwidth.
Example: ":FILT:HPAS:FREQ 300HZ"
Features: *RST value: - (STATe = OFF)
SCPI: conforming
Mode: VA-A
:[SENSe<1|2>:]FILTer:LPASs[:STATe] ON | OFF
This command activates the low-pass filter in the AF-branch with analog demodulation.
Example: ":FILT:LPAS ON"
Features: *RST value: OFF
SCPI: conforming
Mode: VA-A
On switching to ON, a bandwidth of 3 kHz for REAL TIME ON and a bandwidth of 5 PCT for REAL
TIME OFF is set automatically.

Table of Contents