EasyManua.ls Logo

Rohde & Schwarz FSW-K40 - Page 138

Rohde & Schwarz FSW-K40
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands for Phase Noise Measurements
R&S
®
FSW-K40
138User Manual 1173.9286.02 ─ 15
Example:
FETC:PNO:SWE:MDR?
would return, e.g.:
2.17,11.45,105.11,219.37,553.48
Usage: Query only
Manual operation: See "Sweep Result List" on page 18
FETCh:PNOise:SWEep:SRATe?
This command queries the sampling rate used in each half decade.
Return values:
<SamplingRate> Sampling rate as displayed in the Sweep Result List.
The command returns one value for each half decade as a
comma separated list.
Default unit: Hz
Example:
FETC:PNO:SWE:SRAT?
would return, e.g.:
25000,75000,250000,750000,2500000
Usage: Query only
Manual operation: See "Sweep Result List" on page 18
FETCh:PNOise:SWEep:STARt?
This command queries the start frequency offset of each half decade.
Return values:
<Frequency> Frequency offset as displayed in the Sweep Result List.
The command returns one value for each half decade as a
comma separated list.
Default unit: Hz
Example:
FETC:PNO:SWE:STAR?
would return, e.g.:
1000,3000,10000,30000,100000
Usage: Query only
Manual operation: See "Sweep Result List" on page 18
FETCh:PNOise:SWEep:STOP?
This command queries the stop frequency offset of each half decade.
Return values:
<Measurements> Frequency offset as displayed in the Sweep Result List.
The command returns one value for each half decade as a
comma separated list.
Default unit: Hz
Configure Numerical Result Displays

Table of Contents

Related product manuals