EasyManua.ls Logo

Rohde & Schwarz FSW43 - Page 506

Rohde & Schwarz FSW43
1150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Common Analysis and Display Functions
R&S
®
FSW
506User Manual 1173.9411.02 ─ 19
Deactivating All Search Limits ← Search Limits
Deactivates the search range limits.
Remote command:
CALCulate:MARKer:X:SLIMits[:STATe] on page 935
CALCulate:THReshold:STATe on page 936
Positioning Functions
The following functions set the currently selected marker to the result of a peak search
or set other characteristic values to the current marker value. These functions are
available as softkeys in the "Marker To" menu, which is displayed when you press the
MKR -> key.
Peak Search................................................................................................................506
Search Next Peak....................................................................................................... 506
Search Minimum......................................................................................................... 506
Search Next Minimum.................................................................................................506
Center Frequency = Marker Frequency...................................................................... 507
Reference Level = Marker Level................................................................................. 507
Peak Search
Sets the selected marker/delta marker to the maximum of the trace. If no marker is
active, marker 1 is activated.
For spectrogram displays, define which frame the peak is to be searched in.
Remote command:
CALCulate<n>:MARKer<m>:MAXimum[:PEAK] on page 938
CALCulate<n>:DELTamarker<m>:MAXimum[:PEAK] on page 940
Search Next Peak
Sets the selected marker/delta marker to the next (lower) maximum of the assigned
trace. If no marker is active, marker 1 is activated.
For spectrogram displays, define which frame the next peak is to be searched in.
Remote command:
CALCulate<n>:MARKer<m>:MAXimum:NEXT on page 937
CALCulate<n>:DELTamarker<m>:MAXimum:NEXT on page 940
Search Minimum
Sets the selected marker/delta marker to the minimum of the trace. If no marker is
active, marker 1 is activated.
For spectrogram displays, define which frame the minimum is to be searched in.
Remote command:
CALCulate<n>:MARKer<m>:MINimum[:PEAK] on page 939
CALCulate<n>:DELTamarker<m>:MINimum[:PEAK] on page 941
Search Next Minimum
Sets the selected marker/delta marker to the next (higher) minimum of the selected
trace. If no marker is active, marker 1 is activated.
Marker Usage

Table of Contents

Related product manuals