Module Replacement R&S SMB
1407.0806.82 3.52 E-6
Replacing the RF-Board (A200)
(See chapter 5, drawing 1406.6000.01 D and spareparts list 1406.6030.01 ST).
Removing the RF-Board
Note: If the R&S SMB-B1 (Reference Oscillator) option is installed, uninstall this option first (see
Replacing the Reference Oscillator Option R&S SMB-B1 (A210)).
Switch off the instrument and pull the mains plug.
Dismounting the case (see page 3.39).
Disconnect the RF-Cables W212, W214, W215 and the flex. strip W222.