EasyManua.ls Logo

Rosslare AC-825IP - Page 30

Rosslare AC-825IP
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC-825IP Panel Setup
30 AC-825IP Hardware Installation and User Guide
If you wish to extend the cable distance, make sure you use the correct cable
according to the cable color.
Power to the OSDP readers is to be taken from the reader +12 V outputs.
Do not connect more than two readers per each +12 V output.
Some readers are
not supplied with a cable. Please refer to the reader’s manual
for connecting it to the relevant reader port.
OSDP readers MUST be set to addresses 13 and 14.
Refer to the reader specifications for the maximum cable length, typically
150 m (492 ft) with an 18 AWG cable.

Table of Contents

Other manuals for Rosslare AC-825IP

Related product manuals