RDC6332G Control System User Manual
36
/
47
© 2015 Ruida Technology. All Rights Reserved
multiple-origin logic and the “Origin” key on the keyboard become invalid. In such a case,
the parameter of each origin must be set in the menu as follows.
Origin X Enable: After the multiple-origin logic is enabled, the four origins can
independently be prohibited and enabled.
Set Origin 1/2/3/4: after the multiple-origin logic is enabled, you can stop the cursor at
“Set as Origin 1/2/3/4”. Press the “Enter” key on the keyboard and the system will take
the coordinate figures of current X/Y axles as the corresponding ones to the origin 1/2/3/4.
Next Origin: there are five digits as 0~4 for option, which are the origins to be used for
the next figure. Origin 0 means the origin set by the “Origin” key on the panel in the
single-origin logic. 1~4 means the serial number of the origins in the multiple-origin logic.
Next origin can be modified to any one of origin 1~4, so as to control the start location of
the next work (the premise is that the origin is enabled), but it can’t be modified to origin
0.
Once the multiple-origin logic is selected and if the serial number of
the next origin is 1 and four origins are enabled, when the memory
file function is started or the processing file is uploaded into the PC
and this file selects “Take the Original Origin as current Origin”, the
work started for each time will use different origins. The rotation
order of origin is 1->2->3->4->1->2…….
Origin location: There are four entries to be selected: Top Left, Top Right, Bottom Left
and Bottom Right. When one is selected, the previewed graph on the screen would be
enantiomorphous based on X or Y direction.
This item is only used to preview the file on the screen, and it is
invalid to the machine’s movement.
Set Para: After the “Set Para” is selected and the Enter key pressed, the interface will
show the specific password to be entered when set as default parameter. After the
manufacturer regulates all parameters of the machine well (including all manufacturer
parameters and user parameters), this function can be used to store the well-regulated
parameters to help users to recover the original parameters (including all manufacturer
parameters and user parameters) through selecting “Recover Para” when they regulate
parameters improperly.
Recover Para: After the “Recover Para” is selected and the Enter key pressed, the
“Successful Recovery” dialog box will pop up to prompt that all manufacturer parameters
and user parameters are recovered successfully. You can return to the previous menu by
press the Enter key.
Auto Focus: When the cursor stops at “Auto Focus”, press the Enter key to search for the
focus (When there is z-axis, and the z-axis reset function is enabled, the auto-focusing is
valid); press the Esc key to return the prior menu.