SYSTEM STARTUP—SYSTEM CONTROLS
NON-AUTOMATIC MODE
If a momentary contact activator such as a push-button,
pull cord, radio control, etc., is used to operate the door:
The door will open when the device is activated.
After passing through the door, a similar type of
device must be used to close the door.
In summary, in the non-automatic mode, an activator is
used to open and close the door.
Parameter Mode
The control system includes various parameters that
are used to operate your door. A number of parameters
are set at the factory. Other parameters must be set in
the field.
The parameters are organized according to the Opera-
tor/Service Level authorized to access each parameter.
Table 1 lists the parameters available at the Operator
Level. Table 2 lists the parameters available at Service
Level 1. Table 3 lists the parameters available at Service
Level 2.
SYSTEM CONTROLS
All door commands and control system menus are
accessed through a keypad located on the front of the
control panel. The keypad includes three keys: up (
),
down (
), and enter (
).
During normal operation with the door closing or closed,
momentarily pressing the up (
) key will automatically
move the door to the open position. Pressing the down
(
) key will move the door to the closed position. Press-
ing the enter (
) key as the door is moving in either
direction will immediately stop the door.
Service Levels
In addition to operating the door, the up (
), down (
),
and enter (
) keys are used to navigate through the
control system parameters. See “Navigating Parame-
ters” on page 11.
The parameters, beginning on page 15, are grouped
into three service levels.
Operator Level — password not required. Access
limited to: auto-close timers and select defrost con-
trol functions (if configured with defrost control).
Service Level 1 — password required (5). Access
to: Operator Level parameters as described above,
initial door installation startup routine, operator
parameters, and error history.
Service Level 2 — password required (available
only through factory). Access to: Service Level 1
parameters as described above, activator parame-
ters, and other miscellaneous parameters. All
remaining parameters are available as read-only.
The service switch in the control box is factory set to the
on position. This allows access to all password levels.
Access to all parameters can be disabled by placing the
service switch to the off position and locking the control
panel door. Cycling power off and on places the control-
ler in the run mode.
If the controller is in any service level and there is no
keypad activity for 30 minutes, the controller will auto-
matically reset and return to the run mode.