LRF 6742 Integrator Manual
INTEGRATOR MANUAL LRF 6742 918574A
Public: 04.2023
Confidential & Proprietary SAFRAN VECTRONIX AG All rights reserved
Page: 46/63
8.7.5 Query: Get Range Gate Settings >LM,Ig,x*<CS><CR>
This command retrieves the current range gate settings.
The parameter x can only take the values:
x=1 Retrieves the minimum range gate settings.
x=2 Retrieves the maximum range gate settings.
Get current range gate settings command and response
Command
Inputs
Description
>LM,Ig,x*<CS><CR>
>LM,Ig,1*D2<0D>
Get current range gate settings.
Example with x=1, get minimum gate range.
Response
Outputs
Description
>LM,Ig,g*<CS><CR>
> LM,Ig,00000*91<0D>
Response of the LRF module with parameter x=1.
Example with range gate (g) being zero.
Table 18: Get current range gate settings command
Example of a get range gate (min) settings command transaction:
Host LRF Module
Command frame: >LM,Ig,1*D2<0D>
LRF Module Host
Acknowledge frame: >AC*84<0D>
Response frame: >LM,Ig,00000*91<0D>
Prompt: <

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?