5.3 – SAGEM-LINK F Block Diagram
The SAGEM-LINK F Block Diagrams are given in Figure 5.4 (1+0 configuration) and Figure 5.5 (1+1
configuration).
IDU
RSL
Cable Interface Module
Tributaries : 16 x E1
Tributary
Multiplexer &
Demultiplexer
G703
PC
RS232
EOW
Ethernet
10 BaseT
West
East
Mgr
Network
Management
Interface
SNMP
SNMP
SNMP
MGMT1
MGMT2
V11/V28
V11
4 Dry Loop
Inputs
4 Dry Loop
Outputs
5 Alarm
Relays
V11/V28
V11/V28
AUX1
AUX2
9600
Bauds
V11
AUX3
64 kbit/s
Mux/ Demux
Wayside Traffic
Frame
Serial
bus
Microprocessor
Telemetries
Telemetry Uplink
Transmitter
Receiver
Tx LO
Rx LO
IF LO
Downlink
-48V
Uplink
Antenna
Port
140 MHz
5.5 MHz
350 MHz
ODU
10 MHz
QAM Mod.
350 MHz
ASK Mod
19600 bit/s
5.5 MHz
DE
UP
Transmit Data
Receive Data
-48V
QAM
Demod
140 MHz
DR
ASK dem
19600
DN
+5 V
-48 V
10 MHz
Telemetry Downlink
On/Off
(Front Panel)
-48 V
DE
UP
DN
DR
+5 V
A
M
Alarms
serial Bus
Coaxial
Cable
Ethernet
100baseT
Option
Ethernet
100 BaseT
Figure 5.4 – SAGEM-LINK F Block Diagram (1+0)

Table of Contents