SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 128/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Tributaries
Interface types
2x 2, 4x 2, 8x2 or 16x 2 Mbit/s 120 Ω or 75 Ω
Ethernet 100 base T
Physical and electrical specifications
ITU-T G.703 (2 Mbit/s)
Physical and electrical specifications
IEEE IEEE 802.3
Auxiliary Channels and Management Interfaces
Engineering Orderwire 1
point-to-point RJ11
9600 bit/s Auxiliary Channels 2
V.11/V.28 DB9
64 kit/s Auxiliary Channel 1
V.11 co/contra - directional DB15
Alarm Relays 5
interface relay contacts DB37
Input Dry Loops 4
interface relay contacts “
Output Dry Loops 4
interface relay contacts ”
Management Interfaces
PC port V.24/V.28 DB9
Management channels
10 Mbit/s Ethernet interfaces RJ45
9600 to 115200 bit/s MGMT1 interfaces V.11 or V.24/V.28 DB25
9600 to 115200 bit/s MGMT2 interfaces V.11/DB25
Mechanical
Dimensions
Indoor Unit 1U, 19-inch : 44(H) x 485 (L) x 300 (P) mm
Outdoor Units 267 mm Diameter, Height : 89 mm
Weight
Indoor Units 3.5 kg
Outdoor Units (all frequencies) 5 kg
Installation
Indoor Units 19-inch racks
Outdoor Units and antennas 50 to 115 mm poles
Indoor Unit-to-Outdoor Unit interconnection
1+0 1 coaxial cable
1+1 2 coaxial cables
Impedance
50 Ω
Length up to 600 m depending on cable type
Examples
Belden 9914 / VDC=-48V < 230 m
Andrew LDF 4-50/ VDC=-48V < 600 m