Consumption
DC Voltage Input
-36 V to -59 V
Power consumption
1+0 configuration
1+1 configuration
IDU < 25 W (Typical 15 W)
ODU < 40W (Typical 30 W)
85 W Typical
Environmental
Environmental Conditions
(Applicable ETSI standard)
Indoor Unit
Outdoor Unit
ETS 300 019 class 3.1
ETS 300 019 class 4.1
Temperature Range
Indoor Unit -10°C to+50°C
Outdoor Unit -33°C to+55°C
Electromagnetic Compatibility (Applicable ETSI standard)
Transmission EN 301 489-1/4
Immunity EN 301 489-1/4