SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 71/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
3.3.3 - Monitoring Menu
When clicking on the Monitoring menu, this screen appears :
Click here to display
Monitor.log file (text file)
Using Windows Notepad.exe
Click here to edit
Monitor list and to start a
new record
Click here to display
Graphical log
Two Logs are available in SAGEM-LINK F equipments : the monitor log, which periodically record on
the PC hard disk the status of selected events, and the equipment events log which store in the
equipment RAM all events in case of status change.
Monitor log requires to have the PC connected to the SAGEM-LINK F during the whole measurement
time, while equipment event log works without any PC connected.
3.3.3.1 - View Monitor Log
When Clicking on the View Monitor Log, SAGEM-LINK F Pilot starts the Windows Notepad to display
Monitoring file.
This text file contains :
Equipment information
Monitoring parameters selected by the Edit Monitor Log control, with their status when starting
monitoring.
Link monitoring data
As this is a text file, it could be printed or exported to an other program.
Monitoring Messages
Each alarm name is followed by the alarm source: LOCAL for any local alarm and REMOTE for
any remote alarm.
"Normal" means there is no alarm, while an "alarm" indication means an active alarm
Ex : "Transmit Freq 2 REMOTE Alarm" means there is an active transmit frequency alarm in the
transmitter 2 (standby unit) of the far end equipment.
Alarm List
Transmit Power 1 : Transmit power alarm on transmitter 1 (main)
Transmit Power 2 : Transmit power alarm on transmitter 2 (Standby)
Transmit Freq 1 : Transmit frequency alarm on transmitter 1 (main)
Transmit Freq 2 : Transmit frequency alarm on transmitter 2 (standby)
Receive Level 1 : RSL alarm on receiver 1 (main)
Receive Level 2 : RSL alarm on receiver 2 (Standby)
PSU 1 : ODU Power Supply alarm 1 (main)
PSU 2 : ODU Power Supply alarm 2 (standby)
Cable 1 : ODU Cable alarm 1 (main)