EasyManua.ls Logo

Sagem SAGEM-LINK F - Page 72

Sagem SAGEM-LINK F
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 72/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Cable 2 : ODU Cable alarm 2 (standby)
Modulation 1 : Modulator alarm on channel 1 (main)
Modulation 2 : Modulator alarm on channel 2 (standby)
Demodulation 1 : Demodulator alarm on channel 1 (main)
Demodulation 2 : Demodulator alarm on channel 2 (standby)
Link ID Code : Link ID Code alarm
IDU : IDU alarm
BER Warning
BER Alarm
Local Aux Input k : Alarm on auxiliary input k on local equipment (k = 1 to 4)
Remote Aux Input n : Alarm on auxiliary input n on remote equipment (n = 1 to 4)
Tributary i Fault : Alarm on tributary i (i= 1 to 16)
Measurements List
RSL Channel 1 - xx dBm : RSL on channel 1 (main) equal to - xx dBm
RSL Channel 2 - xx dBm : RSL on channel 2 (standby) equal to - xx dBm
BER Channel 1 nE-m : Bit error rate on channel 1 equal to nx10
-m
BER Channel 2 nE-m : Bit error rate on channel 2 equal to nx10
-m
G.821 Quality Data
Period 1mn/15mn/30mn/60mn/24h : G.821 data measuring period
G821 – ES xx : number of errored seconds
G821 – IS xx : number of unavailable seconds
G821 - SES xx : number of seriously errored seconds
G821 - IP xx : number of unavailable periods
G821 - ESR xx % : rate of errored seconds over the measuring period (indicated
above)
G821 - SESR xx % : rate of seriously errored seconds over the measuring period
(indicated above)
G821 - ISR xx % : rate of unavailable seconds over the measuring period
(indicated above)
G.826 Quality Data
Period 1mn/15mn/30mn/60mn/24h : G.826 data measuring period
G826 - ES xx : number of errored seconds
G826 - SES xx : number of seriously errored seconds
G826 - BBE xx : number of residual errored blocks, i.e. errored blocks coming
outside the seriously errored seconds (SES)
G826 - ESR xx % : rate of errored seconds over the measuring period (indicated
above)
G826 - SESR xx % : rate of seriously errored seconds over the measuring period
(indicated above)
G826 - BBER xx % : rate of residual errored blocks over the measuring period
(indicated above)
Events that may occur during monitoring
LOCAL-REMOTE(TSL) Broken/Restored : radio link broken/restored,
IDU-ODU(DCC) Broken/Restored : Communication link between IDU and ODU broken/restored,
TRANSMISSION Channel 1/Channel 2 : channel 1/channel 2 radio transmitter switch,
RECEPTION Channel 1/Channel 2 : channel 1/channel 2 radio receiver switch,
The connection with SAGEM-LINK F
Equipment is broken / restarted
: PC does not communicate with equipment any
more
3.3.3.2 - Edit Monitor List
When Clicking on the Edit Monitor List menu, the following screen appears :

Table of Contents