SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 99/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
Cable Interface Module LEDs
The "Modem" alarm LED lights red, when there is a cable interface module alarm like a
modulator fault, a demodulator fault (receive data not recovered), or a power supply fault. This
alarm is red if the ODU is not connected.
The "RSL" alarm LED lights red, when the current receive signal level is below the RSL
threshold, or when there is a BER degradation (BER alarm, or BER warning active). This alarm
corresponds in most cases to a propagation or to an interferer problem
The "ODU" alarm LED lights red, if there is an ODU alarm, or if there is an ODU not connected.
The "Power" Status indication lights green, when Cable Interface Module is powered.
4.5 - SAGEM-LINK F Pilot Alarm Menus
SAGEM-LINK F Pilot software provides information on link status and alarm information. These
informations are available in the main screen and in the alarm menu. Refer to chapter 3 for Pilot
description
4.5.1 – Alarms Screen
Click on the alarm menu (refer to chapter 3 section 3.3.2 for description). Click on the "All alarms" tab
to have a complete view of all available alarms (local or remote terminal). All active alarms are
indicated with a red color.
The description of all available SAGEM-LINK F alarms is given below :
ODU Alarms Description Corrective action
ODU PSU
Power Supply Alarm returned from the ODU. This
alarm is active when there is a default in the ODU
Check DC Power supply, and cable
losses. If the cable and DC power are