2.9 - BER Measurement
This test is to be done from one side of the link with all tributaries linked with a daisy chain
arrangement as described in Figure 2.5 and Figure 2.6.
In case of a problem due to an interferer, it should be necessary to measure the two directions
separately and to proceed to a frequency scan.
For a 1+1 system, as the verification of the different units have already been made, the quality test
shall be performed only with main channels (automatic mode).
A BER test using G821 parameters shall be performed for a duration depending on the network :
30 minutes for low capacity links (GSM, Wifi,…)
24 hours for medium and high capacity links
An other amount of time could be used for this test, but this will require Sagem approval.
Figure 2.5 : Link Quality Measurement
.