3.3.8 – Changing an IDU Configuration
SAGEM-LINK F IDU can be used for 1+0 unprotected systems or for 1+1 protected system without
any hardware change.
There are four possible configurations : 1+0, 1+1 HSB (Hot Standby), 1+1 SD (Space diversity) and
1+1 FD (Frequency Diversity).
SAGEM-LINK F Pilot allows to modify the current configuration to a new one. This change is made
without any ODU connected.
Procedure :
Switch off the IDU
Remove any ODU connection
insert one cable interface module for a 1+0 equipment or two cable interface modules for a 1+1
system
Switch on the IDU without any ODU connected and run the Sagem-Link F Pilot software in
super user mode
Click on the button indicating IDU configuration
Click here to modify current
IDU configuration