Loading...
SAGEM-LINK F 288055571-04
Installation and Operation Manual
Page 94/142
Issue 04 : July 2005
Reproduction and communication prohibited without the written permission of Sagem Communication
3.3.7.6 – Frequency Scan
Frequency scan is a special function of SAGEM-LINK F Pilot used to measure receive spectrum
around receive frequency, in order to identify radio interferers which could degrade the link sensitivity.
The results are displayed graphically and are stored in the IDU flash memory for further consultation.
Frequency scan is to be performed separately on each terminal. The user defines maximum and
minimum frequencies to scan. The local transmitter is muted, while the system measure Receive
Signal Levels frequency per frequency.
Note : To proceed to a frequency scan, it is necessary firs to change the current capacity and
modulation to a 2 E1/QPSK mode.
When clicking on the frequency scan menu this windows appears :
Click here to view a previous scanClick here to start a frequency scan
Define scan frequency range
Define the scan frequency range by moving the cursors, start by clicking on the Proceed button. The
frequency scan starts and the following screen is displayed :
Once the frequency scan is complete, the result is displayed graphically. Frequency step and
resolution bandwidth filter are 3.5 MHz. The result is automatically stored in the IDU.

Table of Contents