2.5 - Tributary Tests
These tests are to be done on both ends of the link.
Using a BER analyzer with G821 capability, test all used 2 Mbit/s access.
BER Analyzer Settings :
Transmit to Receive test
2 Mbit/s
Internal Clock
PRBS : 2
15
-1.
120 Ohm balanced, or 75 Ohm unbalanced depending on IDU configuration.
All used tributaries are to be tested one by one :
Click on the button
(top left of the toolbar on main screen) or use the menu : "Tools /
Tributaries". The tributary screen appears.
Verify that the tributary under test is configured in normal mode (N), with active service
(A), and no loopback (blank button).
All other tributaries should be unconnected and configured as inverted (I)
Normally there should be a local tributary alarm.
Connect a 2 Mbit/s BER analyzer on the tributary input. Be sure to use a cable in the same
impedance (refer to "Interface" indication). The tributary alarm should be now cleared.
Click on the loopback button to have access to loopback configuration screen, and select a
remote loopback for the tributary under test. (For loopback procedure refer to Chapter 3,
section 3.2.4).
Verify on the BER analyzer that there is no error occurred during one minute
Once the test has been done, disconnect the cable, and change Data alarm in invert mode
(I), and remove remote loopback for this tributary.
Repeat this test for all used tributaries.